中字幕人妻一区二区三区-国产成 人 综合 亚洲奶水-女人被狂躁c到高潮喷水一区二区-蜜臀性色av免费-蜜桃臀av高潮无码

您的位置: 首頁 > 技術文章 > Acrel anti-backflow meter apply in the Philippines photovoltaic project

Acrel anti-backflow meter apply in the Philippines photovoltaic project

更新日期:2021-11-09瀏覽:781次

1.Background

    With the development of photovoltaic industry, the capacity of village-level transformers and industrial power transformers and the installed capacity of photovoltaic projects are saturated in some areas.The power grid company requires the photovoltaic grid-connected system to be a non-backflow current generation system, which means that the electricity generated by the photovoltaic grid-connected system is consumed by the local load, and the excess electricity is not allowed to be sent to the upper power grid through the low-voltage distribution transformer in reverse direction.

    Photovoltaic inverter in photovoltaic components will produce direct current into alternating current (ac), has the dc component and harmonic mixing, unbalanced three phase current, output power of uncertainty, such as the current basic didn't take effective management measures, therefore, when there is power to the utility grid, will generate harmonic pollution to power network, easy cause power grid voltage fluctuation and flicker, etc.,If there are many such power sources to transmit electricity to the grid, the power quality of the grid will be seriously degraded.Therefore, this kind of photovoltaic power generation system must be equipped with anti-backflow current facilities to prevent the occurrence of reverse power.

    When the photovoltaic power generation is greater than the load demand, the inverse power will be generated.So we need instruments to determine that Inverter has power output, and then by the instrument through RS485 communication signal and inverter data interaction, adjust the inverter output power, so that its output power and power balance.

2.Project Overview

    A photovoltaic power generation company in the Philippines contacted our company to look for anti-backflow current meters. After proper connection agreement, we will purchase ACR10R-D16TE from our company.

3.Anti-backflow detection meter

    When the photovoltaic power generation is greater than the load demand, reverse power will be generated. Therefore, we need an meter to determine that the inverter has over-power output, and then the meter sends a signal through RS485 communication to interact with the inverter data to adjust the output power of the inverter to balance the output power and the electrical power.

1.png

4.Function 

2.png

4.png

5.Wiring


6.Typical Connection

7.png

Bibliography

1.Solutions for enterprise micro-grid system 


 

Contact Us
  • 郵箱:2885080326@qq.com
  • 地址:上海市嘉定區育綠路253號

掃一掃  微信咨詢

©2025 安科瑞電氣股份有限公司 版權所有    備案號:滬ICP備05031232號-79    技術支持:智慧城市網    Sitemap.xml    總訪問量:238441    管理登陸

電瓶車充電樁禁止非法改裝

主站蜘蛛池模板: 国产在线高清视频无码| 亚洲午夜精品久久久久久人妖| 少妇系列之白嫩人妻| 欧美一区欧美二区| 熟女一区二区中文| 国产精品亚洲精品日韩已满十八小 | 色伦专区97中文字幕| 久久久无码精品亚洲日韩蜜桃| 国产99久一区二区三区a片| 久久免精品一区二区| 国产精品激情偷乱一区二区 | av无码免费岛国动作片不卡| 国产成人一区二区无码不卡在线| 一区二区三区中文字幕在线观看 | 欧美激情一区二区在线视频| 欧美大片一区二区三区| 免费人成在线观看网站| a狠狠久久蜜臀婷色中文网| 日本xxxx裸体xxxx视频大全| 国产午夜无码片在线观看影视| 人人妻人人澡av| 高清一区二区91| 久久精品成人无码观看不卡| 伊人久久久大香线蕉综合直播| 免费毛片在线看片免费丝瓜视频| 国产精品岛国久久久久| 久久伊人热热精品中文字幕| 欧美亚洲一区二区三区啪啪| 亚洲嫩模一区二区三区| 久久人人爽av亚洲精品天堂 | 丝袜一区二区三区在线播放| 亚洲欭美日韩颜射在线二| 午夜福利久久一区| 一本色综合久久| 国产亚洲日韩欧美另类第八页| 精品无码综合一区二区三区| 国产美女露脸口爆吞精| 欧美蜜桃一区二区三区在线观看| 色婷婷在线精品国自产拍| 激情偷乱人成视频在线观看| 亚洲午夜国产精品无码|